Plant Optimization News - Power Engineering https://www.power-eng.com/om/plant-optimization/ The Latest in Power Generation News Fri, 02 Aug 2024 18:42:12 +0000 en-US hourly 1 https://wordpress.org/?v=6.6.1 https://www.power-eng.com/wp-content/uploads/2021/03/cropped-CEPE-0103_512x512_PE-140x140.png Plant Optimization News - Power Engineering https://www.power-eng.com/om/plant-optimization/ 32 32 Coal plant’s AI drives down emissions, boosts efficiency https://www.power-eng.com/om/plant-optimization/coal-plants-ai-drives-down-emissions-boosts-efficiency/ Fri, 02 Aug 2024 18:42:09 +0000 https://www.power-eng.com/?p=125219 There’s plenty of hype surrounding AI— no matter the industry. But clear applications are emerging from the clutter, and power generators are getting a taste of the technology’s potential.

One of the largest generators in the U.S., Vistra, tapped McKinsey & Company to develop a machine-learning model to improve the efficiency and emissions of the coal-fired Martin Lake Power Plant in Rusk County, Texas.

The effort began when Vistra wanted to build and deploy a heat-rate optimizer (HRO) for the plant. The company worked with McKinsey data scientists and machine learning engineers from QuantumBlack AI to build a “multilayered neural-network model,” or an AI-powered algorithm that learns about the effects of complex nonlinear relationships.

The team fed the model two years of plant data to see which combination of external factors and internal decisions could produce the optimal HRO for any given time. External factors included temperature and humidity, and internal decisions included variables that operators can control.

It wasn’t a “one-and-done” solution, though. Vistra’s team continued to provide guidance on how the plant worked and identified data sources from sensors, which McKinsey said helped its engineers refine the model by adding and removing variables to see how the heat rate changed.

Through the training process and “introducing better data,” the models eventually made predictions with 99% accuracy or higher. After running the model through a series of real-world tests, the engineers turned the model into an “AI-powered engine.” After implementing the engine, the plant’s operators received recommendations every 30 minutes on how to improve the plant’s heat-rate efficiency.

“There are things that took me 20 years to learn about these power plants,” said Lloyd Hughes, Vistra’s operations manager. “This model learned them in an afternoon.”

With higher efficiency came more carbon reduction. Martin Lake was running more than 2% more efficiently after three months of operating with the machine-learning tool, which McKinsey said resulted in savings of $4.5 million per year and 340,000 tons of abated carbon.

Following the success at the Martin Lake Power Plant, Vistra distributed the AI-enabled HRO to another 67 generation units across 26 plants, which resulted in an average of 1% improvement in efficiency, McKinsey said, in addition to more than $23 million in savings.

Overall, Vistra’s AI initiatives have helped the company avoid around 1.6 million tons of carbon per year, McKinsey said.

Read the full case study here.

]]>
https://www.power-eng.com/wp-content/uploads/2024/08/1920px-Martin_Lake_Power_Plant_Tatum_Texas_2019.jpg 1920 1080 https://www.power-eng.com/wp-content/uploads/2024/08/1920px-Martin_Lake_Power_Plant_Tatum_Texas_2019.jpg https://www.power-eng.com/wp-content/uploads/2024/08/1920px-Martin_Lake_Power_Plant_Tatum_Texas_2019.jpg https://www.power-eng.com/wp-content/uploads/2024/08/1920px-Martin_Lake_Power_Plant_Tatum_Texas_2019.jpg
Trends in plant O&M with EthosEnergy’s Terry Schoenborn https://www.power-eng.com/om/trends-in-plant-om-with-ethosenergys-terry-schoenborn/ Fri, 12 Jul 2024 21:47:18 +0000 https://www.power-eng.com/?p=124962 Recent Integrated Resource Plans (IRPs) indicate that U.S. utilities are planning for the largest increase in natural gas-fired power plants in over a decade. Buyers of F-Class, advanced-class and aeroderivative gas turbines are reportedly experiencing lead times not seen since the early 2000s.

Terry Schoenborn has certainly noticed this renewed interest, which he attributes to projected rising electricity demand from data centers and manufacturing.

“In the last 10 years, there hasn’t been as many new greenfield sites going in, but we’re starting to see some of that activity pick up,” said Schoenborn, who is Senior Vice President of Operations and Maintenance (O&M) at EthosEnergy.

This was just one trend discussed in a recent interview with Schoenborn, who highlighted the evolving market dynamics that are shaping plant O&M.

Plants are changing hands

Schoenborn told us there is a lot of Merger & Acquisition (M&A) activity right now in the power generation market, driven by factors like the Inflation Reduction Act and a renewed interest in reliable gas capacity.

“I just think it’s a dynamic market right now,” he said, “and there are opportunities for investors to take advantage.”

As assets flip, adaptation is important for EthosEnergy, which has operated more than 100 generation facilities (mostly gas) dating back to its inception in 2014.

For example, the company was recently awarded O&M contracts for six natural gas combined-cycle (NGCC) plants in Mexico. This was shortly after the Iberdrola-owned facilities were sold to private equity firm Mexico Infrastructure Partners (MIP).

When EthosEnergy takes over O&M for multiple, let alone six plants at once, the process of scaling up manpower and training can be challenging. The work starts with assessing the condition and staffing levels of those facilities.

Schoenborn said some plants EthosEnergy takes on are in good condition and others require more care and effort.

“We may have to have more resources, spend time at that plant to get it up to speed or the level that our customers expect,” said Schoenborn.

A plant’s condition often depends on where it is in its lifecycle and how much a customer thinks it can extract out of it, he said.

“It could be just as simple as, if the customer knew they were selling the asset, they are probably not going to invest as much into it,” he said. “So it just gets into disrepair.”

While EthosEnergy has close to 800 employees in its O&M division, the company has brought in approximately 100-150 just in the last two years as it has taken on new contracts.

The importance of peaking power

Gas turbines are taking an increasingly important role as peaking power sources, since they can be ramped up and down quickly to meet demand spikes, filling in gaps when renewable resources are not generating electricity.

For that reason EthosEnergy earlier this year launched its Houston-based Performance Center, where the company monitors generators in 20 different countries.

The center combines 24/7 remote start-stop capabilities with monitoring and diagnostics. EthosEnergy operators control start-stop operations through encrypted cyber-secure VPN technology. They can use video surveillance to monitor a customer’s assets using real-time thermal imaging.

Inside EthosEnergy’s Performance Center in Houston. Courtesy: EthosEnergy.

Schoenborn noted a lot of peaking plants with low capacity factors are fully-staffed and operate almost on-call. He said using the performance center is a good solution to optimize the reliability of these assets that sit idle most of the time, and from a cost perspective.

“We felt like it was a something we needed to have to play in this market,” Schoenborn told us.

Schoenborn said the capabilities of the performance center have opened up new discussions with customers, particularly as the energy transition may run slower than anticipated.

As customers target aggressive net-zero goals, EthosEnergy works with them to develop realistic maintenance strategies. Schoenborn emphasized the importance of maintaining reliability without overinvesting in assets that could be repurposed or shut down in the near-future.

“How we’re working with them is saying, ‘Let’s really sit down and talk about what maintenance you need to have to make sure you maintain the same level of reliability,’” he said.

Watch the full interview with Terry Schoenborn above.

]]>
https://www.power-eng.com/wp-content/uploads/2024/07/schoenborn.png 780 570 https://www.power-eng.com/wp-content/uploads/2024/07/schoenborn.png https://www.power-eng.com/wp-content/uploads/2024/07/schoenborn.png https://www.power-eng.com/wp-content/uploads/2024/07/schoenborn.png
Emerson’s James Fraser on automation, optimizing data from renewables https://www.power-eng.com/renewables/emersons-james-fraser-on-automation-optimizing-data-from-renewables/ Fri, 06 Oct 2023 06:00:00 +0000 https://www.power-eng.com/?p=121222 Transitioning to cleaner energy systems or scaling up existing ones is a complex undertaking for power producers.

Companies may have purchased or brought various wind turbines, solar farms or batteries into their portfolios. They often ask Emerson how they can integrate the data points from all of these assets into one place for optimal decision making.

That’s where Ovation Green comes in. To learn more, Power Engineering sat down with Emerson’s James Fraser at the company’s Emerson Exchange Immerse event in Anaheim, California.

“I heard a phrase yesterday in the exhibition hall: Frankenstein automation,” said Fraser, who is Vice President for Global Renewables of Emerson’s Power and Water Solutions. “You’ve got all these disparate pieces of equipment. And what we do with Ovation Green is allow access to information which is completely independent of the OEM.”

Emerson was already known for its Ovation platform, a control and automation system designed to help power plant operators with real-time monitoring and control of equipment, processes and systems.

But as the market has shifted toward renewables in the last few years, the company has made a series of strategic acquisitions to augment its expertise and technology platforms.

This all led up to the launch of Ovation Green earlier in 2023.

“It’s that understanding of the customer and where their challenges are that are the most important,” said Fraser. “We have the technology, we have the software, we have the capability. It’s then, how do you put those things together?”

By gathering and contextualizing vast amounts of data from renewable generation and storage assets, Emerson says the Ovation Green platform will drive faster, more informed decisions to increase availability and production while reducing operations and maintenance costs. 

Fraser said customers will better be able to understand or predict an asset reliability issue or make better economic decisions for dispatching power onto the grid.

Because the platform was designed with renewables in mind, he said asset owners will be able to report performance data to regulators more seamlessly.

Asset information through Ovation Green could be housed onsite, at a fleet management office or in the cloud.

“We give that flexibility of choice, because everybody has a slightly different requirement,” said Fraser.

See the full one-on-one video above.

]]>
https://www.power-eng.com/wp-content/uploads/2023/10/emerson-exhange-2.png 619 554 https://www.power-eng.com/wp-content/uploads/2023/10/emerson-exhange-2.png https://www.power-eng.com/wp-content/uploads/2023/10/emerson-exhange-2.png https://www.power-eng.com/wp-content/uploads/2023/10/emerson-exhange-2.png
Researchers say new coating could boost efficiency at coal and gas plants https://www.power-eng.com/om/plant-optimization/researchers-say-new-coating-could-boost-efficiency-at-coal-and-gas-plants/ Wed, 23 Aug 2023 17:11:24 +0000 https://www.power-eng.com/?p=120923 Researchers at the University of Illinois Urbana-Champaign say they’ve developed a coating for steam condensers used in steam-cycle generation that could boost process efficiency by 2% at coal- and natural gas-fired plants.

This research was originally published in the journal Nature Communications. Teams said the coating, made with fluorinated diamond-like carbon, or F-DLC, is suited for industrial use after researchers subjected coated metals to steam condenser conditions for 1,095 days, the longest durability test they’d reported. The coated metals maintained their hydrophobic properties for this entire length of time.

According to the university, the new F-DLC coating improves heat transfer because the material is hydrophobic. When the steam condenses into water, it does not form a thin film that coats the surface, like water does on many clean metals and their oxides.

Instead, researchers said the water forms droplets on the F-DLC surface, putting the steam into direct contact with the condenser and allowing heat to be directly transferred. The researchers reported this translating to a 2% overall process boost.

Researchers said if fossil-burning plants were 2% more efficient, then, every year, there could be 460 million fewer tons of carbon dioxide released and 2 trillion fewer gallons of water used.

“A lot of CO2 is going to be emitted before we get to a place where we can lean on renewable,” said Nenad Miljkovic, a professor of mechanical science and engineering at UIUC and the project lead.  If our F-DLC coating were adopted globally, it would noticeably curtail carbon emissions and water usage for the existing power infrastructure.”

The research team will now study the coating’s performance for six months of steady condensation exposure under industrial conditions at the university’s Abbott Power Plant.

]]>
https://www.power-eng.com/wp-content/uploads/2023/08/CondenserPipes.png 450 298 https://www.power-eng.com/wp-content/uploads/2023/08/CondenserPipes.png https://www.power-eng.com/wp-content/uploads/2023/08/CondenserPipes.png https://www.power-eng.com/wp-content/uploads/2023/08/CondenserPipes.png
Trace metal analyses for corrosion monitoring in cogeneration condensate systems https://www.power-eng.com/om/plant-optimization/trace-metal-analyses-for-corrosion-monitoring-in-cogeneration-condensate-systems/ Wed, 23 Aug 2023 16:37:50 +0000 https://www.power-eng.com/?p=120915 By Brad Buecker – Buecker & Associates, LLC

Introduction

In previous Power Engineering articles, we examined the importance of trace iron monitoring to determine the extent of carbon steel corrosion in heat recovery steam generator (HRSG) condensate and feedwater circuits. (1, 2) HRSG feedwater systems typically contain no copper alloys, except perhaps rarely a condenser with copper alloy tubes. However, cogeneration and large industrial steam systems may have numerous heat exchangers containing copper alloy tubes.

Accordingly, both iron and copper monitoring of condensate are important for evaluating the efficacy of chemical treatment programs in minimizing corrosion and the secondary effect of corrosion product transport to steam generators. In this article, we will briefly revisit several important aspects of steam generator condensate/feedwater iron analyses. We will also examine why copper monitoring is needed at cogeneration facilities, along with modern analytical methods for trace metal analysis.

Some background history

During the age of large fossil plant construction in the middle of the previous century, the condensate/feedwater network typically contained several closed feedwater heaters plus an open heater, the deaerator.

Copper alloys were a common materials choice for closed feedwater heater tubes because of copper’s excellent heat transfer properties. However, copper is susceptible to corrosion from the combined effects of dissolved oxygen and ammonia, the latter being the common chemical for feedwater pH control (although at some plants alkalizing, aka neutralizing, amines remain the choice). (3, 4)

Oxygen converts the protective Cu2O layer on the copper surface (where copper is in the +1 oxidation state) to CuO, with copper transforming to a +2 oxidation state. Cu2+ reacts with ammonia to form a soluble compound. So, for virtually any system containing copper alloys, a combination of mechanical deaeration and chemical oxygen scavenging was, and still is, necessary to protect the alloys. The oxygen scavenger also serves as a passivating agent to convert CuO back to Cu2O.

The combination of ammonia or an ammonia/amine blend for pH control and oxygen scavenger feed is known as all-volatile treatment reducing (AVT(R)). It produces the familiar dark magnetite layer (Fe3O4) on carbon steel but is no longer recommended for utility units and HRSGs with no copper alloys.

Rather, all-volatile treatment oxidizing (AVT(O)) as outlined in Reference 1 (with no oxygen scavenger feed but still ammonia or an ammonia/amine blend for pH control) is the proper choice. AVT(O) produces a red oxide layer, α-hematite (alternatively known as ferric oxide hydrate (FeOOH)) on carbon steel. AVT(O) requires high-purity feedwater with a cation conductivity of <0.2 mS/cm to be successful. For cogeneration and industrial steam generation systems, the (usually) lower-purity feedwater and/or presence of copper alloy-tubed heat exchangers prohibits AVT(O), with AVT(R) being the required option.

Careful chemistry control is necessary to find the balance between minimal iron and copper corrosion. A key ingredient in the treatment program is corrosion product monitoring to ensure that the chemistry is optimized.

Corrosion product monitoring

Regarding iron monitoring, several discussion points from Reference 2 bear brief repetition. 

Typically, 90% or greater of steel corrosion products exist as iron oxide particulates. Thus, measurements of just dissolved iron do not come close to the total corrosion product concentration. Hach developed a benchtop procedure that utilizes a 30-minute digestion process to convert all iron to soluble form for subsequent analysis on a standard spectrophotometer.

Figure 2. Combination reagent, digestion vials and heater block (left); 1” sample cell (center) and spectrophotometer (right). Photos courtesy of Hach.

 

The lower detection limit is 1 part-per-billion (ppb), which is satisfactory for even high-pressure steam generators where the recommended feedwater iron concentration is <2 ppb. As events have shown over the last nearly four decades, iron monitoring is highly important for tracking flow-accelerated corrosion (FAC) in condensate/feedwater systems and in the low-pressure economizer and evaporator (and often some intermediate pressure circuits) of multi-pressure HRSGs. This benchtop technique provides snapshot readings only, but those are often sufficient with a system protected by proper chemistry. (5)

Sometimes, however, continuous online measurements are important to quickly detect changing conditions. Hach has developed a laser nephelometry technique for that purpose, with additional details available in Reference 2. This method must be calibrated at each site and is dependent on whether an AVT(O) or AVT(R) program is in place. 

Now we reach a second key point of this article, as summarized in Reference 5.

For a cogeneration plant that sends steam to a steam host for use in a process (either via direct or indirect use) and then receives all or a portion of the condensate back, monitoring corrosion products in the steam condensate indicates whether corrosion and FAC are minimized in the process part of the steam plant. . . .  For mixed-metallurgy plants the copper levels can be extremely variable depending on the plant design and operation, but with chemistry optimized as far as possible, levels of total copper less than 10 [ppb] can be expected.

As with iron, the analytical process must account for dissolved and particulate metal. When this author began his power plant career over four decades ago as a laboratory chemist, the lab was equipped with a flame/graphite furnace atomic absorption spectrophotometer (AAS). Sample acidification with nitric acid solubilized particulate copper, and the total could then be accurately analyzed by the AAS. However, many labs do not have such sophisticated equipment and the trained personnel to operate these instruments. One method for accurate measurements, albeit where samples are collected over time, is corrosion product sampling.

Figure 3. A common corrosion product sampler (CPS). Photo courtesy of Sentry Equipment Corp.

This CPS utilizes a fine-pore mechanical filter paper for particulate collection and cation exchange (and if desired anion exchange) filter papers for dissolved ion collection. Any sampling period may be chosen (one to two weeks is common), after which the filters are sent to a laboratory for accurate analyses. The unit has a precise flow totalizer so that the analytes can be converted to concentration units for the time-period that the sample was collected. 

Consider the extract below from the recently-revised industrial boiler water guidelines produced by the American Society of Mechanical Engineers (ASME).

Figure 4. Data extracted from Table 1 of Reference 6 – “Suggested Water Chemistry Targets Industrial Water Tube with Superheater” (The complete guidelines are available from the ASME at very reasonable cost and should be in the library of any industrial plant with steam generators.)

As the reader will note, recommended feedwater iron and copper limits are stringent, even for low-pressure industrial steam generators, and the values decrease with increasing pressure. For high-pressure utility steam generators, the suggested upper limits are 2 ppb for both iron and copper. A CPS can provide very valuable data on corrosion control in condensate systems with mixed metallurgies. Consider the following example, in which a CPS assisted with corrosion monitoring in a utility steam generator.

CPS case history

The author once consulted for an electric utility whose main unit was and still is a coal-fired boiler at full-load operating conditions of 1, 900psig drum pressure and 1, 005°F main and reheat steam temperatures. The feedwater system had heaters with copper-alloy tubes, requiring an AVT(R) feedwater chemistry regimen. (At the time of this project, plant personnel were developing a plan to replace the copper alloy heater tubes with steel.) Carbohydrazide served as the reducing agent, with a blend of morpholine and cyclohexylamine for pH conditioning.  Chemical injection is at the deaerator storage tank. Even though the chemical feed system could maintain feedwater pH within a range of 9.0–9.3 (the recommended range for balancing steel and copper corrosion control), the condensate pH typically remained in an 8.8–8.9 range.  It became clear that the condensate pH depression resulted from amine decomposition products that carried over with the steam.(4)

Per our recommendation, utility personnel installed a Sentry corrosion product sampler, with the flexibility for monitoring either feedwater or condensate pump discharge (CPD). Sampling indicated that iron concentrations were often five to fifteen times greater than the 2-ppb recommended limit, which suggested serious flow-accelerated corrosion in the condensate/feedwater network. Furthermore, the iron concentrations in the CPD were higher than in the feedwater. These results suggested that the lower pH induced by alkalizing amine decomposition had more of an influence on mild steel corrosion than the higher feedwater temperatures, both of whose influences are well known per the following famous diagram.

Figure 5. Feedwater carbon steel dissolution as a function of pH and temperature. Note: The pH analyses were performed at 25o C.(7) In high-purity water, an exponential correlation exists between pH and ammonia concentration, which is represented on the graph.

Regarding copper analyses, the CPS revealed concentrations very near the 2-ppb limit mentioned above, which should be expected in an oxygen-free environment with a pH close to 9.0. Accordingly, carbon steel corrosion became the primary focus in this unit. Plant personnel have recently incorporated a film-forming amine (FFA) into the chemical treatment program. Film-forming amines and related non-amine products are designed to directly establish a protective layer on metal surfaces. (8) Both successful and unsuccessful applications have been reported, but space does not permit a detailed discussion at present. In this application, no CPS data is yet available to confirm the efficacy of the FFA, but Millipore filter tests suggest that carbon steel corrosion has been reduced.   

Film-forming chemistry should be incorporated into and not serve as a full-blown substitute for either AVT(R) or AVT(O) methodologies. An issue that has been problematic regarding FFA applications is direct calculation of reagent concentrations. Significant strides are being made in this respect, which Hach personnel highlighted in a paper at the recent Electric Utility Chemistry Workshop. (9)

While copper monitoring has proven to be less critical than iron monitoring in the example above, it is often much more important at cogeneration and industrial steam plants. As mentioned, certain conditions such as the combination of dissolved oxygen and ammonia can cause significant copper corrosion and reduce the life expectancy of heat exchanger tubes. 

Another corrodent that can cause severe damage to many metals including copper is sulfide (S2-). The author once observed a situation where thousands of new 90-10 copper-nickel tubes in a steam surface condenser failed from multiple pitting leaks within 18 months because the machining lubricant contained sulfide that was not removed before the tubes were placed in service. An online measurement often recommended for chemistry control in mixed-metallurgy systems is oxidation-reduction potential (ORP). The data provided by trace metal monitoring methods can be correlated to ORP measurements to then serve for continuous chemical feed control.

Conclusion

Trace metal monitoring continues to become better recognized as a critical tool for optimizing steam generator chemical treatment programs and controlling corrosion. A primary concern with utility units is minimizing carbon steel flow-accelerated corrosion, but for cogen and industrial steam/condensate networks, copper corrosion monitoring is often also very important.


References

  1. B. Buecker, “HRSG Steam Generation Issues: Reemphasizing the Importance of FAC Corrosion Control, Parts 1-4” Power Engineering, September-October 2022.
  2. Buecker, B., Kuruc, K., and L. Johnson, “The Integral Benefits of Iron Monitoring for Steam Generation Chemistry Control”; Power Engineering, January 2019.
  3. B. Buecker, Tech., Ed., Water Essentials.  (The new ChemTreat industrial water handbook, currently being released in digital format at www.chemtreat.com.)
  4. Shulder, S. and B. Buecker, “Remember the 3Ds of Alkalizing Amines: Dissociation, Distribution, and Decomposition”; PPCHEM Journal, 2023/01.
  5. International Association of the Properties of Water and Steam, Technical Guidance Document: Corrosion Product Sampling and Analysis for Fossil and Combined Cycle Plantswww.iapws.org.
  6. Consensus on Operating Practices for the Control of Feedwater and Boiler Water Chemistry in Modern Industrial Boilers, The American Society of Mechanical Engineers, New York, NY, 2021.
  7. P. Sturla, Proceedings of the Fifth National Feedwater Conference, Prague, Czechoslovakia, 1973.

        

]]>
https://www.power-eng.com/wp-content/uploads/2023/08/image-3.png 639 531 https://www.power-eng.com/wp-content/uploads/2023/08/image-3.png https://www.power-eng.com/wp-content/uploads/2023/08/image-3.png https://www.power-eng.com/wp-content/uploads/2023/08/image-3.png
Wet limestone FGD solids analysis by thermogravimetry https://www.power-eng.com/om/plant-optimization/wet-limestone-fgd-solids-analysis-by-thermogravimetry/ Mon, 08 May 2023 16:54:11 +0000 https://www.power-eng.com/?p=120242 By Brad Buecker, Buecker & Associates, LLC

In a recent article for Power Engineering [1], I wrote about the special properties of limestone, and especially high-purity stone, that have made it a common flue gas desulfurization reagent for numerous coal-fired power plants over the last five decades. Of course, in many areas of the world coal-fired power is being phased out, which makes flue gas desulfurization (FGD) chemistry moot to some readers.  However, coal-fired power plants are still common in some countries. And, as I was reminded from feedback to the previous article, many metal-ore smelting facilities exist around the globe where a principal emission is gaseous sulfur dioxide. Wet-limestone FGD (WFGD) scrubbing is becoming a proven process for these applications. [2]

Accurate analysis of scrubber solids is critical for determining reaction efficiency and limestone utilization. This article outlines a technology that a colleague and I helped pioneer in the power industry way back in the late-1980s [3], but which may be unfamiliar to many plant personnel today. The technique is thermogravimetry (TGA). The analytical method allowed us to eliminate time-consuming and often inaccurate wet-chemistry test methods and improve scrubber performance. I brought the concept with me to a second coal-fired power plant, where TGA again proved its value. [4]

TGA analysis of scrubber byproduct

Analysis by thermogravimetry is simple in concept. A TGA functions by weighing samples on a precise analytical balance as they are heated. The main features of some designs are a top mounted balance, vertically supported sample pan, an automatically-operated furnace that raises for sample analysis and lowers when analysis is complete, an automatic sample loader, and a personal computer for instrument operation and data analysis. The furnace compartment typically has a port that allows samples to be analyzed in various atmospheres via bottled gases that are connected to the compartment by a manifold, tubing system, and automated sample-switching device. Nitrogen is common to provide an inert atmosphere that eliminates oxidation reactions that might occur with air. Additional discussion of this topic appears later in this document.

A TGA is a quantitative not a qualitative instrument, so the operator needs to have a good idea of the primary constituents in the sample before analysis. If the compounds decompose at distinct and separate temperatures, it becomes easy to calculate the concentration of the original materials. Wet-limestone scrubber byproducts lend themselves well to this technique. (The reader can refer to Reference 1 for a more detailed description of scrubber process chemistry.) The following equations illustrate the decomposition temperatures and chemistry of wet-limestone FGD solids.

CaSO4·2H2O –> CaSO4 + 2H2O­  (160oC to 200oC)            Eq. 1

(CaSO3·CaSO4) ·½H2O –> CaSO3·CaSO4 + ½H2  (400oC to 430oC) Eq. 2

CaCO3 –> CaO + CO2­  (650oC to 800oC)    Eq. 3

Figure 2 illustrates a TGA analysis of a pre-dried scrubber solids sample from Reference 4 containing all three of the major constituents listed above. For the moment, we will ignore the decomposition shown at 600oC.  This will be addressed shortly.

The calculations to determine constituent concentrations are straightforward. The molecular weight of gypsum is 172 and that of the water forced out is 36, so the initial gypsum content is determined by multiplying the weight loss (5.772 percent) times a factor of 172 ÷ 36 (4.78). For calcium sulfite-sulfate hemihydrate, the factor is 131.9 ÷ 9 (14.6), where the mole ratio of calcium sulfite to calcium sulfate is assumed to be 85:15. For the calcium carbonate decomposition, the factor is 100.1 ÷ 44 (2.27). Thus, for the analysis shown in Figure 2, the gypsum content is 27.6 percent, the calcium sulfite-sulfate hemihydrate content is 12.0 percent, and the calcium carbonate content is 22.3 percent.

This sample came from a wet-limestone scrubber that served the dual purpose of removing SO2 and the fly ash from the flue gas of a Cyclone boiler. The fly ash loading was much lower than it would have been for a pulverized coal unit, but nonetheless the unburned carbon effects upon the analyses were important. We first attempted to analyze the scrubber solids in a nitrogen atmosphere from beginning to end of the run, but found that volatile discharge and accompanying weight loss from the unburned carbon blended in with the calcium carbonate decomposition. So, we modified the procedure to introduce air to the furnace at 600oC. (We subsequently lowered the temperature to 500oC). The step was isothermal with a 20-minute hold time that allowed all volatile matter and carbon to burn away. The effect is clearly illustrated by the vertical slope at 600oC in Figure 2. Following the isothermal hold step, the computer automatically resumed sample heating to a final temperature of 1000oC. This step clearly separated the carbon vaporization from the calcium carbonate decomposition.

When this boiler and scrubber were installed, no plans were in place to produce a high-gypsum byproduct for potential sale. In part, this probably was because of the relatively poor-quality limestone in the area (CaCO3 content less than 90%), which would not have produced a high-purity byproduct. Instead, the scrubber solids were discharged as a slurry to large, lined holding ponds. Some readers may ask why byproduct analyses were needed at all with the slurry being discarded.  Two answers emerged quickly. Initial TGA data indicated unused CaCO3 concentrations in the byproduct of 15-25%, as is evident in Figure 3. When we informed plant operators of this gross inefficiency, they adjusted limestone grinding mill settings to produce a finer reagent size. Subsequently, the unused limestone concentrations dropped to 5-10%, which translated into a large savings in limestone costs. Also, and again referring to Figure 3, a rise in unburned carbon content in the daily scrubber samples typically indicated a problem with one or more of the boiler’s coal crushers. The lab technicians would usually detect such upsets before the boiler operators, so they made it a point to notify the operators immediately after seeing a sample weight loss due to carbon decomposition. This allowed for expedient adjustments of a poorly performing coal mill.

High-purity byproduct analyses

My initial work with TGA, which extended over half a decade, was with a forced-oxidation, wet-limestone scrubber that was designed to produce a byproduct suitable for sale to wallboard manufacturers. The required gypsum concentration was 94% or greater. Figure 3 is an analysis of the typical byproduct. (Like many other units in the US, the boiler and scrubber have been retired.)

TGA proved extremely valuable in helping plant chemists verify that the forced oxidation system was operating properly. For starters, the TGA data showed that the scrubber manufacturer had not installed sufficient oxidation capacity to convert all of the calcium sulfite (CaSO3) to CaSO4. Per language in the original contract, the supplier had to install an additional air compressor to ensure complete oxidation.

Following this correction, we periodically noticed an oxidation loss per TGA data. Investigation revealed that the high temperatures of the oxidation air would cause crystal deposition at the openings in the perforated air-injection laterals. As airflow to the slurry dropped the loss of oxidation efficiency was detectable due to an increase in (CaSO3·CaSO4)·½H2O. The unit manager had a water injection system installed to the lateral headers that lowered the oxidation air temperature and eliminated the scale formation.

In another very prominent example of the TGA importance at this plant, over a two-year period we performed several full-scale tests on limestones in close proximity to the plant to see if we could lower transportation costs of the material. All of these stones were of lower quality than the standard. Performance data confirmed that none were suitable as a replacement; a conclusion which in large part was confirmed by TGA results that showed a significant drop in byproduct gypsum content and a significant rise in unreacted CaCO3.

A Quirky Observation

For those contemplating use of a TGA for FGD solids analyses, a special point should be noted. The author discovered early on that calcium sulfite will break down at high temperatures when analyzed in an atmosphere devoid of oxygen. A colleague found a description of this chemistry in a somewhat obscure reference that I no longer have. 

CaSO3 –> CaO + SO2­           Eq. 4

This phenomenon reappeared during subsequent work at my second utility. Figure 4 illustrates this effect.

The trained analyst can distinguish the end of the calcium carbonate decomposition and the beginning of the calcium sulfite decomposition. This transition is apparent at the shoulder in the decomposition pattern at 750oC. The calcium sulfite breakdown can be eliminated by analyzing the sample in air, and Figure 5 shows a duplicate sample as analyzed in an air atmosphere.

Rather than decompose, a portion of the calcium sulfite appears to oxidize to calcium sulfate at the high temperature, but I do not have actual confirmation of this chemistry.

Conclusion

Thermogravimetry is an excellent method for tracking wet-limestone FGD chemistry, especially when quick results are required, when checking for process upsets, and when making process changes. While its application in the coal-fired power industry may not be as valuable as in the past, it is a technique that may be valuable for other industries such as metal refining, where SO2 scrubbing may be an important process.


References

  1. B. Buecker, “Limestone – The Amazing Scrubbing Reagent”; Power Engineering, April 2023. www.power-eng.com.
  2. “Antimony Roaster Project: FGD Flue Gas Desulfurization Plant”; The ERG Group, www.ergapc.co.uk
  3. Buecker, B., and D. Dorsey, “TGA Identifies Scrubber Materials”; Research and Development, Vol. 28, No. 5, May 1986.
  4. B. Buecker, “Wet Limestone FGD Solids Analysis by Thermogravimetry”; paper for the 24th Annual Electric Utility Chemistry Workshop, May 11-13, 2004, Champaign, Illinois

Brad Buecker is president of Buecker & Associates, LLC, consulting and technical writing/marketing.  Most recently he served as Senior Technical Publicist with ChemTreat, Inc.  He has over four decades of experience in or supporting the power and industrial water treatment industries, much of it in steam generation chemistry, water treatment, air quality control, and results engineering positions with City Water, Light & Power (Springfield, Illinois) and Kansas City Power & Light Company’s (now Evergy) La Cygne, Kansas station.  Buecker has a B.S. in chemistry from Iowa State University with additional course work in fluid mechanics, energy and materials balances, and advanced inorganic chemistry.  He has authored or co-authored over 250 articles for various technical trade magazines, and has written three books on power plant chemistry and air pollution control.  He may be reached at beakertoo@aol.com.

]]>
https://www.power-eng.com/wp-content/uploads/2023/05/image.png 395 498 https://www.power-eng.com/wp-content/uploads/2023/05/image.png https://www.power-eng.com/wp-content/uploads/2023/05/image.png https://www.power-eng.com/wp-content/uploads/2023/05/image.png
Grid-edge R&D and natural gas power plant wow attendees of POWERGEN 2023 https://www.power-eng.com/powergen/grid-edge-rd-and-natural-gas-power-plant-wow-attendees-of-powergen-2023/ Tue, 21 Feb 2023 14:00:00 +0000 https://www.power-grid.com/?p=102521 Cutting edge power technology is a cornerstone of every POWERGEN International, the annual event for the power generation industry, which is running in Orlando, Florida this last full week of February.

While the conference and exposition officially begin on Tuesday, February 21, enthusiastic attendees from all over the globe flew in early to take in a tour of the Orlando Utilities Commission (OUC) Gardenia Innovation and Operations Center followed by a tour of the 740-MW Cane Island Power Park.

Grid-edge R&D

OUC’s facility is where the municipal utility tests pre-commercialized or newly commercialized technology and includes a floating solar array, a vehicle-to-grid bi-directional charger, a 50-kW DC fast charger (soon to be upgraded to 120 kW), several Level 2 EV chargers, a 10-kW/40-kWh vanadium redox flow battery and two underground 8-kW/32-kWh flywheels.

“We want to make sure we understand how they work, their operational characteristics and build new business cases around them before we put them in a position where they could be affecting our customers,” explained Rubin York, one of the three OUC engineers leading the tour.

Flywheels flank the combiner box at OUC’s Gardenia Innovation and Operations Center

In addition, OUC is testing a site controller that can operate the system in three main modes: PV smoothing, demand mitigation, which performs autonomous peak shaving, and contingency mode, which collects the assets into a microgrid.

“That is only possible thanks to these flywheels,” said York.

They go through a grid-forming bi-directional inverter which, in contingency mode, assess the frequency and voltage of the buildings and meters and disconnects the EV chargers, the PV inverter (per the IEEE standard), and any other load until the flywheels can output a good 60 hertz, 480-volt AC signal, said York. Once the flywheel generation is firm, OUC can slowly bring the loads back up and charge the EVs.

York also showed off the Cloud Impact Mapping System (CIMS), an in-house developed system that was designed to predict the ramp rate of solar PV as clouds come over and depart the solar PV. Should the technology scale, it could prove to be useful to electric utilities in Florida that are relying on a large amount of solar PV generation because Florida generally experiences a large amount of clouds.

“The goal is to build an array of these all around our territory, build a central repository, and have them effectively ‘hand off’ cloud systems to one another,” said York.

The OUC Gardenia site is also host to a rooftop solar array with bifacial solar panels and a solar parking canopy, which covers the parking lots for the facility.

Control Center at Cane Island Power Park

Exceptional availability

After a quick bus ride and lunch, attendees toured the 740-MW Cane Island Power Park, which was available more than 90% of the time in the 2021 and won an award for its exceptional availability.

Unit 3 of the park ran for eight months with no trips said Ken Rutter, COO of the Florida Municipal Power Agency (FMPA), which owns the plant along with Kissimmee Utility Authority (KUA). He added that the unit ran through Hurricane Ian and supplied power to customers who were able to accept it.

The POWERGEN group was split into four smaller groups and taken all throughout the park, viewing each generating unit, one turbine (that was not currently operating), condensers, cooling towers, the control center, and more.  Rutter encouraged attendees to ask their tour guides anything at all – and they certainly took him up on that offer.

Cooling Towers at Cane Island Power Park

POWERGEN International 2024 takes place in New Orleans, January 23-25, 2024.

]]>
https://www.power-eng.com/wp-content/uploads/2023/02/Unit3CaneIslandPowerPark-3.jpg 750 563 https://www.power-eng.com/wp-content/uploads/2023/02/Unit3CaneIslandPowerPark-3.jpg https://www.power-eng.com/wp-content/uploads/2023/02/Unit3CaneIslandPowerPark-3.jpg https://www.power-eng.com/wp-content/uploads/2023/02/Unit3CaneIslandPowerPark-3.jpg
Constellation extends nuclear maintenance contract with Allied Power https://www.power-eng.com/nuclear/constellation-extends-nuclear-maintenance-contract-with-allied-power/ Mon, 13 Feb 2023 16:57:09 +0000 https://www.power-eng.com/?p=119496 Follow @KClark_News

Allied Power will continue to provide maintenance at 12 Constellation nuclear plants through mid-August 2028, per an extension signed by the companies. The new agreement includes staff augmentation and has an option for a five-year renewal.

The 12 plants are located in Illinois, Maryland, New York and Pennsylvania.

Allied Power provides a range of services, from routine maintenance to outage services and management, capital construction and specialized support – for power plants throughout the U.S.

Constellation is the largest owner and operator of nuke plants in the U.S. In October 2022 we reported the Exelon spinoff plans to ask the Nuclear Regulatory Commission (NRC) to extend the operating licenses of its Clinton and Dresden nuclear plants in Illinois by an additional 20 years.

If approved by the NRC, Clinton could operate until 2047 and Dresden could operate until 2049 (Unit 2) and 2051 (Unit 3).

]]>
https://www.power-eng.com/wp-content/uploads/2022/04/byron-30.jpeg 720 463 https://www.power-eng.com/wp-content/uploads/2022/04/byron-30.jpeg https://www.power-eng.com/wp-content/uploads/2022/04/byron-30.jpeg https://www.power-eng.com/wp-content/uploads/2022/04/byron-30.jpeg
GSE to develop hydrogen plant model for NuScale SMR simulator https://www.power-eng.com/nuclear/gse-to-develop-hydrogen-plant-model-for-nuscale-smr-simulator/ Mon, 06 Feb 2023 15:51:06 +0000 https://www.power-eng.com/?p=119448 Follow @KClark_News

GSE Solutions announced it will work with NuScale Power on a hydrogen plant model for NuScale’s small modular reactor (SMR) power plant simulator.

It comes after a recent announcement that several partners would assess the potential of hydrogen production using electricity and process heat from NuScale’s SMR.

The idea is to modify the existing NuScale control room simulator to include GSE’s models for hydrogen production. This would include modeling for a solid oxide electrolysis system to produce hydrogen, in addition to a fuel cell for electricity production.

Research will consider the number of NuScale power modules needed for use in solid oxide fuel cell hydrogen production and the quantity of hydrogen stored for subsequent electricity production.

The scaled–up model is estimated to be complete by the middle of March 2024.


Portland-based NuScale’s power module is a small pressurized water reactor, which can generate 77 MW of electricity (MWe). Its six-module VOYGR-6 can generate 462 MWe. The company also offers a 12-module VOYGR-12 (924 MWe) and a four-module VOYGR-4 (308 MWe).

VOYGR is the official name of NuScale’s SMR, which it plans to deploy for Utah Associated Municipal Power Systems’ (UAMPS) Carbon Free Power Project (CFPP) at the Idaho National Lab (INL).

The CFPP project’s first module is projected to come online in 2029, with all six modules online by 2030. NuScale believes the six-module CFPP will act as a catalyst for subsequent SMR plant deployments across the U.S. and beyond.

Hydrogen is viewed as a way to decarbonize energy systems. In these markets, hydrogen would be used as an end-use product or as a stored energy source to be processed through a solid oxide fuel cell for electricity generation.

]]>
https://www.power-eng.com/wp-content/uploads/2023/01/NuScale-VOYGR-SMR-plant-NuScale.jpg 730 410 https://www.power-eng.com/wp-content/uploads/2023/01/NuScale-VOYGR-SMR-plant-NuScale.jpg https://www.power-eng.com/wp-content/uploads/2023/01/NuScale-VOYGR-SMR-plant-NuScale.jpg https://www.power-eng.com/wp-content/uploads/2023/01/NuScale-VOYGR-SMR-plant-NuScale.jpg
Model aims to optimize black start grid restoration https://www.power-eng.com/news/model-aims-to-optimize-black-start-grid-restoration/ Fri, 27 Jan 2023 19:02:20 +0000 https://www.power-eng.com/?p=119372 A team of researchers at Sandia National Laboratories created a computer model aimed at helping grid operators quickly restore power to the electric grid after a blackout.

According to the Sandia scientists, the model combines a restoration-optimization model with a computer model of how grid operators would make decisions when they don’t have complete knowledge of every generator and distribution line.

Researchers say the model can help provide insight into how individual power generators, distribution substations and power lines would react during the process of restoring power.

The model also can simulate black starts that are triggered by disruptions such as a successful cyberattack.

In terms of optimizing restoring power, the model assesses the grid and its components to determine how to restore power as quickly as possible, said Bryan Arguello, a Sandia computer scientist.

Arguello said an example of an optimal approach might be to start with generator 1 to power up substation A. Once substation A is energized, generators 2-4 can safely power up. These, in turn, will provide power to substations B, C and D, as well as some critical infrastructure such as a water purification plant or an area hospital. Once substation D is energized, power plants 5-8 can power up, and so on until power is restored to the entire grid.

Once the power-restoration schedule is developed, the algorithm compares it against physical limitations to determine if the schedule is feasible, Arguello said. This process is based off a similar model created by researchers at Lawrence Livermore National Laboratory and the University of California Berkeley.

“The challenge here is bringing in just the right amount of information so that the model can make wise decisions, without bogging it down in too much detail,” said Arguello.

The model can also accurately approximate alternating current power flow, according to the researchers, which they say is more complex than direct current. The model also offers a more accurate representation of the grid during severe disruptions such as black start conditions.

Modeling operator decision-making

The operator decision-making code plays an essential role in the overall model, researchers said.

This algorithm takes the results from the optimization code and enacts it on a third code, which they described as a “physics-based simulation of the grid and how it dynamically responds to the operator’s actions.”

The decision-making model is based on a model created by scientists at Carnegie Mellon University, but adapted for power restoration by coding in expert knowledge about the steps required to start a generator and then connect it to the nearest substation.

This also includes safeguards so the cognitive model wouldn’t freeze if the grid behaved unexpectedly, Sandia scientists said.

The operator model interacts with the grid model through a simulated console and is limited to the knowledge presented by the console, rather than presuming the grid operator knows everything, which is typically assumed in power-restoration models.

Researchers said the operator model can assess whether the network model’s behavior matches up with what it is expecting based on the results of the optimization algorithm. The simulated console can also allow the team to swap in actual feeds of information from the grid for the network dynamic model, if a partner provides the information, they added.

“Black starts are really rare, extreme events, but when one happens it’s really bad,” said Systems Analyst Casey Doyle. “Even in partial blackouts, like what happened in Texas in 2021, people died because they didn’t have power, they didn’t have heat. If you have a complete blackout, it’s likely that it would be caused by a hurricane or earthquake and operators are trying to restore power to whole communities. Delays in power restoration could cause even more damage or loss of life. It’s hugely impactful to understand how to bring the power back as quickly as possible.”

The three-year project was funded by Sandia’s Laboratory Directed Research and Development program. The researchers are currently looking for sponsors to continue and expand the project.

Click here for more on the effort.

]]>
https://www.power-eng.com/wp-content/uploads/2023/01/sandia.png 1090 710 https://www.power-eng.com/wp-content/uploads/2023/01/sandia.png https://www.power-eng.com/wp-content/uploads/2023/01/sandia.png https://www.power-eng.com/wp-content/uploads/2023/01/sandia.png